Maintenance and cleaning SFE 25/50

The filters should be cleaned regularly (every 2 weeks up to 2 months).

The maintenance activities in the table below indicated by [1] can be carried out by the user; other activities are strictly reserved for qualified personnel.

image-20241218-081418.png

Cleaning instructions:

1.- Removing the filters

  • Switch off the unit by turning the main switch (fig. 4A).

  • Loosen the star knobs and open the door

  • Remove the pre filter, ioniser, collector and the after filter (in this sequence).

2.- Cleaning the pre and after filters

  • Clean the pre and after filters in hot water (approx. 60°C) added with a detergent for domestic use. This treatment can be repeated several times. Cleaning with a high-pressure spraying pistol is also possible.

  • Allow for complete drying after cleaning.

3.- Cleaning of the ioniser and collector (Use a detergent specially developed specially developed for electrostatic cleaners.)

  • Clean the ioniser and collector in hot water (approx. 60°C) to which a 2% Plymovent EFC solution has been added. Cleaning using a high-pressure spraying pistol is also possible.

  • Check the ioniser during washing for broken ionisation wires. These broken wires can simply be replaced.

  • Check the collector during washing for bent lamellas. These can be carefully straightened with a screwdriver. Lamellas in contact with each other can cause short-circuiting.

  • Allow for complete drying after cleaning.

4.- Mounting the filters

  • Mount the filters, removed earlier, in reverse order.

Note the correct position of the ioniser and collector. For this purpose, both filters have arrows indicating the direction of the airflow. Pay due attention to the position of the contact pin and contact spring.

image-20241218-085446.png

Clean or replace the filters:

  • when damaged

  • when the ioniser and/or collector starts to make a crackling sound (indicator starts blinking or stops being lit)

  • when the extraction capacity becomes inadequate

If you need a replacement of the pre-filters you cann order it at te following link:

Aluminum pre-filter – Giesen Coffee Roasters

If you need the ioniser, collector and after filter please send us an email to shop@giesen.store

WARNING:

  • Overdue maintenance can cause fire.

  • Always switch OFF the machine and remove the mains plug from the wall socket before carrying out the activities below. First read the maintenance regulations.

  • Polluted filters often contain dust and dirt particles that could be a health hazard when inhaled. When replacing the filter, always wear a reliable and approved facemask.

  • If you encounter a problem, it is advisable to first determine if the issue is mechanical or electrical. The electrical system should only be inspected or repaired by qualified and authorized service personnel.